Parts data

Panasonic Inverter (Untuk Single CSE, CSXE, dan multi CSME)

H11> Communication Failure (Faulty Wiring or other problem with ID to OD communication)
H12> ID/OD Compatibility Problem (Over or Under indexed multi system)
H14> Indoor Air Sensor Faulty (Sensor Disconnected, Faulty or Contacts Dirty)
H15> Compressor Sensor Faulty (Sensor Disconnected, Faulty or Contacts Dirty)
H16> Current Transformer Problem (Power Transistor Module or Outdoor PCB Faulty. Very Low Gas)
H19> Indoor Fan Motor Locked (Fan Motor of Indoor PCB Failure)
H21> Float Switch Operated (Check Drainage)
H23> Indoor Pipe Sensor Faulty (Sensor Disconnected, Faulty or Contacts Dirty)
H27> Outdoor Air Sensor Faulty (Sensor Disconnected, Faulty or Contacts Dirty)
H28> Outdoor Pipe Sensor Faulty (Sensor Disconnected, Faulty or Contacts Dirty)
H30> Outdoor Discharge Sensor 1 Faulty (Sensor Disconnected, Faulty or Contacts Dirty)
H32> Outdoor Discharge Sensor 2 Faulty (Sensor Disconnected, Faulty or Contacts Dirty)
H33> Incorrect Connection Voltage (Indoor or Outdoor Voltage Incorrect/Faulty Wiring)
H34> Outdoor Heat Sink Sensor Faulty (Sensor Disconnected, Faulty or Contacts Dirty)
H36> Outdoor Gas Sensor Faulty (Sensor Disconnected, Faulty or Contacts Dirty)
H37> Outdoor Liquid Sensor Faulty (Sensor Disconnected, Faulty or Contacts Dirty)
H39> Abnormal Indoor Operation (Incorrect Piping or Expansion Valve Problem)
H41> Abnormal Wiring or Piping (Wiring or Piping Crossed on a Twin System)
H97> Outdoor Fan Failure (Outdoor Fan Motor or PCB Failure)
H98> Indoor Coil Overheat (Heat Mode) (Dirty Filters or Indoor Coil. Very High Room Temperature)
H99> Indoor Coil De-Ice (Cool Mode) (Dirty Filters or Indoor Coil. Low Gas Charge or Low Ambient Temp)
F11> Reversing Valve Failure (Faulty Reversing Valve, Coil or Outdoor PCB)
F17> Standby Units Freezing (Multi Only. Expansion Valve Leakage)
F90> PFC Failure (Problem with Inverter or Compressor)
F91> Refrigeration Cycle Problem (Low Gas or Blockage)
F93> Compressor Abnormal Revolution (Compressor Running Incorrectly)
F95> Outdoor Coil Overheat (Cool Mode) (Dirty Condensor Coil, low gas or blockage)
F96> IPM or Compressor Overheating (Excess or Low Gas Charge or dirty heat exchanger)
F97> High Discharge/Compressor Temp (Low Gas Charge or Failed Compressor)
F98> Overcurrent Protection (Outdoor Heat Exchanger Problem. Excess Gas)
F99> DC Overcurrent Protection (Outdoor PC, Power Transistor or Compressor Failure)


1. Data thermostat digital dan settingan parameter chiller freezer GEA 4doors (restoran museum Antonio Blanco)



2. Data thermostat digital dan setting parameter chiller GEA 2doors (restoran pundi-pundi pengosekan)

Tidak ada komentar:

Posting Komentar